|
ENVIROLOGIX
Inc. - Human Exposure Monitoring Kits
METOLACHLOR
MERCAPTURATE (ELISA Kit)
| |
Intended Use
|
The
EnviroLogix Metolachlor Mercapturate In Urine Plate
Kit Is Designed For The Quantitative Laboratory Detection
Of Metolachlor Mercapturate Residues In Human Urine
Samples, With A Quantitative Assay Range From 8 To 85
Parts Per Billion (ppb).
| |
General |
The
EnviroLogix Metolachlor Mercapturate in Urine Plate
Kit is a competitive Enzyme-Linked ImmunoSorbent Assay
(ELISA). In the test, Metolachlor Mercapturate residues
in the sample compete with an enzyme (horseradish peroxidase)
labeled Metolachlor Mercapturate analogue for a limited
number of antibody binding sites on the inside surface
of the test wells. After a simple wash step, the outcome
of the competition is visualized with a color development
step. As with all competitive immunoassays, sample
concentration is inversely proportional to color development.
Darker
color = Lower concentration
Lighter
color = Higher concentration
The
EnviroLogix Metolachlor Mercapturate in Urine Plate
Kit can be used in the following testing applications:
- Human
Exposure Monitoring (Applicators, Handlers, Farm Workers).
- Public
Health Screening Programs.
- Health
Risk Assessment.

| Materials
Provided: |
Materials Required
But Not Provided: |
|
8
x |
Strips
of 12 Antibody-Coated Wells each, in plate
frame. |
|
1 x |
Vial
of Negative Control. |
|
1 x |
Vial
of 8 ppb Metolachlor Mercapturate Calibrator
(Actual Concentration = 0.16 ppb*)
|
|
1 x |
Vial
of 25 ppb Metolachlor Mercapturate Calibrator
(Actual Concentration = 0.5 ppb*). |
|
1 x |
Vial
of 85 ppb Metolachlor Mercapturate Calibrator
(Actual Concentration = 1.7 ppb*). |
|
1 x |
Bottle of Enzyme Conjugate. |
|
1 x |
Bottle
of 10x Sample Diluent.
|
|
1 x |
Bottle of Substrate. |
|
1 x |
Bottle
of Stop Solution. |
| * |
The
difference between the stated and actual concentration
is to correct for the 1:50 dilution required
for sample preparation. |
|
|
Disposable
Tip, Adjustable Air Displacement Pipette
which will measure 980 microliters (µL),
100 µL, and 20 µL. |
|
|
Glass
Test Tubes. |
|
Marking
Pen (indelible). |
|
|
Tape or Parafilm. |
|
Timer
(1 hour and 30 minutes). |
|
|
Distilled
Water. |
|
Cool
Tap Or Distilled Water for rinsing wells. |
|
|
Microtiter
Plate Reader or strip reader. |
|
Microtiter
Plate Washer (optional). |
|
|
Twelve-Channel Pipette that will measure 100
µL (optional). |
|
Racked
Dilution Tubes for loading samples into the
plate with a 12-channel pipette (optional). |
|
|
Orbital
Plate Shaker (optional).
|
|
| Kit
Specifications: |
| Plate
Format: |
|
| Time
Requirement: |
|
| Detection
Limit: |
|
| Quantification
Limit: |
|
Cross
Reaction:
(Limit
Of Detection) |
- Metolachlor
Mercapturate (5 ppb).
- Alachlor
Mercapturate (63 ppb)
-
Atrazine Mercapturate (510000 ppb).
-
Acetochlor Mercapturate (175 ppb).
-
Metolachlor ESA (40 ppb).
-
Alachlor ESA (915 ppb).
-
Acetochlor ESA (9050 ppb).
|
| Measurement: |
- Microtiter
Plate Reader or Strip Reader.
|
| Product
ID #: |
|
|