ENVIROLOGIX Inc. - Human Exposure
Monitoring Kits
ATRAZINE
MERCAPTURATE (ELISA
Kit)
| |
Intended Use
|
The
EnviroLogix Atrazine Mercapturate In Urine Plate Kit
Is Designed For The Quantitative Laboratory Detection
Of Atrazine Mercapturate In Human Urine, With An Assay
Range From 2.0 To 150 Parts Per Billion (ppb).
| |
General |
|
The
EnviroLogix Atrazine Mercapturate in Urine Plate Kit
is a competitive Enzyme-Linked ImmunoSorbent Assay (ELISA).
In the test, Atrazine Mercapturate residues in the diluted
sample compete with enzyme (horseradish peroxidase)-labeled
Atrazine for a limited number of antibody binding sites
on the inside surface of the test wells. After a simple
wash step, the outcome of the competition is visualized
with a color development step. As with all competitive
immunoassays, sample concentration is inversely proportional
to color development.
Darker
color = Lower concentration
Lighter
color = Higher concentration
The EnviroLogix Atrazine Mercapturate in Urine Plate
Kit can be used in the following testing applications:
-
Human Exposure Monitoring (Applicators, Handlers,
Farm Workers).
- Public
Health Screening Programs.
- Health
Risk Assessment.

| Materials
Provided: |
Materials Required
But Not Provided: |
|
|
8
x |
|
Strips
of 12 Antibody-Coated Wells each, in plate
frame |
|
|
1
x |
|
Vial
of Negative Control |
|
|
1
x |
|
Vial
of 2 ppb Atrazine Mercapturate Calibrator
(Actual Concentration = 0.04 ppb*). |
|
|
1
x |
|
Vial
of 20 ppb Atrazine Mercapturate Calibrator
(Actual Concentration = 0.4 ppb*). |
|
|
1
x |
|
Vial
of 150 ppb Atrazine Mercapturate Calibrator
(Actual Concentration = 3.0 ppb*). |
|
|
1
x |
|
Bottle
of Atrazine-Enzyme Conjugate. |
|
|
1
x |
|
Bottle
of 10 x Sample Diluent |
|
|
1
x |
|
Bottle
of Substrate. |
|
|
1
x |
|
Bottle
of Stop Solution. |
| |
|
* |
The
difference between the stated and actual concentration
is to correct for the 1:50 dilution required
for sample preparation. |
|
|
Disposable
Tip, Adjustable Air Displacement Pipette,
which will measure 980 microliters (µL),
150 µL, 100 µL, 50 µL and
20 µL. |
|
|
Marking
Pen (indelible). |
|
Tape
or Parafilm. |
|
|
Timer
(15 and 30 minutes). |
|
Cool
Tap Or Distilled Water for rinsing wells. |
|
|
Microtiter
Plate Reader or strip reader. |
|
Microtiter
Plate Washer (optional). |
|
|
Twelve-Channel
Pipette that will measure 50 µL, 100
µL and 150 µL (optional). |
|
Racked Dilution Tubes for loading samples
into the plate with a 12-channel pipette (optional). |
|
|
Orbital
Plate Shaker (optional).
|
|
| Kit
Specifications: |
| Plate
Format: |
|
| Time
Requirement: |
|
| Detection
Limit: |
|
| Quantification
Limit: |
|
Cross
Reaction: (Limit
Of Detection) |
-
Alachlor Mercapturate (0.5 ppb).
- Atrazine
(0.95 ppb).
-
Alachlor Mercapturate (>50000 ppb).
-
Acetochlor Mercapturate (>50000 ppb).
-
Metolachlor Mercapturate (>50000 ppb).
-
Alachlor ESA (>50000 ppb).
- Acetochlor
ESA (>50000 ppb).
-
Metolachlor ESA (>50000 ppb). .
|
| Measurement: |
-
Microtiter Plate Reader or strip reader.
|
| Product
ID #: |
|
|