ENVIROLOGIX
Inc. - Environmental & Food Monitoring Kits: Pesticides
IMIDACLOPRID For Water Testing (ELISA Kit)
| |
Intended Use
|
The
EnviroLogix Imidacloprid Plate Kit Is Designed For The
Quantitative Laboratory Detection Of Imidacloprid Pesticide
Residues In Ground And Surface Water Samples, With An
Assay Range From 0.2 To 6 Parts Per Billion (Ppb).
| |
General |
|
The
EnviroLogix Imidacloprid Plate Kit is a competitive
Enzyme-Linked ImmunoSorbent Assay (ELISA). In the test,
Imidacloprid pesticide residues in the sample compete
with enzyme (horseradish peroxidase) labeled Imidacloprid
for a limited number of antibody binding sites on the
inside surface of the test wells. After a simple wash
step, the outcome of the competition is visualized with
a color development step. As with all competitive immunoassays,
sample concentration is inversely proportional to color
development.
Darker
color = Lower concentration
Lighter
color = Higher concentration
The
EnviroLogix Imidacloprid Plate Kit can be used in the
following applications:
- Source
Water Protection.
- Drinking
Water Monitoring.
- Treated
Effluent Monitoring.
- Run-Off
Assessment And Monitoring.
- Point
Source Testing.
- Seed
Treatment Quality Control.
| Materials
Provided: |
Materials Required
But Not Provided: |
|
|
8
x |
|
12
Antibody-coated wells, in plate frame.
|
|
|
1
x |
|
Vial
of Imidacloprid Negative Control.
|
|
|
1
x |
|
Vial
of 0.2 ppb Imidacloprid Calibrator.
|
|
|
1
x |
|
Vial
of 1 ppb Imidacloprid Calibrator |
|
|
1
x |
|
Vial
of 6 ppb Imidacloprid Calibrator. |
|
|
1
x |
|
Bottle
of Imidacloprid-enzyme Conjugate.
|
|
|
1
x |
|
Bottle
of Substrate. |
|
|
1
x |
|
Bottle
of Stop Solution. |
|
|
Disposable
tip, adjustable air displacement pipette which
will measure 100 mL. |
| |
Marking
pen (indelible). |
|
Tape
or Parafilm. |
|
|
Timer
(1 hour and 30 minutes). |
|
|
Cool tap or distilled water for rinsing wells. |
|
|
Microtiter plate reader or strip reader. |
|
|
Microtiter plate washer (optional). |
|
|
Twelve-channel pipette that will measure 100
mL (optional). |
|
|
Racked dilution tubes for loading samples
into the plate with a 12-channel pipette (optional). |
|
|
Orbital plate shaker (optional).
|
|
| Kit
Specifications: |
| Plate
Format: |
|
| Time
Requirement: |
|
| Detection
Limit: |
|
| Quantification
Limit: |
|
| Cross
Reaction: |
-
Imidacloprid.
-
Imidacloprid Olefin.
-
DesNitro Imidacloprid.
-
Imidacloprid Urea.
-
Thiamethoxam.
|
| Measurement: |
-
Microtiter Plate Reader or strip reader.
|
| Product
ID #: |
|
|