| ENVIROLOGIX
Inc. - Environmental & Food Monitoring Kits: Pesticides
ISOPROTURON (ELISA Kit)
| |
Intended Use |
The EnviroLogix Isoproturon Plate Kit
Is Designed For The Quantitative Laboratory Detection
Of Isoproturon Pesticide Residues In Ground And Surface
Water Samples, With An Assay Quantification Range From
0.05 To 1.5 Parts Per Billion (Ppb).
| |
General |
|
The
EnviroLogix Isoproturon Plate Kit is a competitive Enzyme-Linked
ImmunoSorbent Assay (ELISA). In the test, Isoproturon
pesticide residues in the sample compete with enzyme
(horseradish peroxidase) labeled Isoproturon for a limited
number of antibody binding sites on the inside surface
of the test wells. After a simple wash step, the outcome
of the competition is visualized with a color development
step. As with all competitive immunoassays, sample
concentration is inversely proportional to color development.
Darker
color = Lower concentration
Lighter
color = Higher concentration
The
EnviroLogix Isoproturon Plate Kit can be used in the
following applications:
- Source Water Protection.
- Drinking
Water Monitoring.
- Treated Effluent Monitoring.
- Run-Off Assessment And Monitoring.
- Point Source Testing.
- Soil Testing.

| Materials
Provided: |
Materials Required
But Not Provided: |
|
8 x |
Strips
of 12 Antibody-Coated Wells each, in plate
frame. |
|
1 x |
Vial
Negative Control. |
|
1 x |
Vial
of 0.05 ppb Isoproturon Calibrator (in deionized
water). |
|
1 x |
Vial
of 0.25 ppb Isoproturon Calibrator (in deionized
water).
|
|
1 x |
Vial
of 1.5 ppb Isoproturon Calibrator (in deionized
water). |
|
1 x |
Bottle
of Isoproturon-enzyme Conjugate. |
|
1 x |
Bottle
of Substrate. |
|
1 x |
Bottle of Stop Solution. |
|
|
Disposable
Tip Adjustable Air Displacement Pipette which
will measure 100 µL. |
| |
Marking
Pen (indelible). |
|
Tape
or Parafilm. |
|
Timer
(1 hour and 30 minutes). |
|
Cool
Tap or Distilled Water for rinsing wells. |
|
Microtiter
Plate Reader or strip reader |
|
Microtiter Plate Washer (optional). |
|
Twelve-Channel
Pipette that will measure 100 µL (optional). |
|
Racked
Dilution Tubes for loading samples into the
plate with a 12-channel pipette (optional). |
|
Orbital Plate Shaker (optional). |
|
| Kit
Specifications: |
| Plate
Format: |
|
| Time
Requirement: |
|
| Detection
Limit: |
|
| Quantification
Limit: |
|
Cross
Reaction: (Limit
Of Detection) |
- Isoproturon
(0.005 ppb).
-
Chlortoluron (9.5 ppb).
-
Monuron (9.0 ppb).
-
Diuron (5.0 ppb).
-
Linuron (385 ppb).
-
Fluometuron (83 ppb).
|
| Measurement: |
-
Microtiter Plate Reader or Strip Reader.
|
| Product
ID #: |
|
|