ENVIROLOGIX
Inc. - Environmental & Food Monitoring Kits: Pesticides
METALAXYL (ELISA Kit)
| |
Intended Use
|
The EnviroLogix Metalaxyl Plate Kit
Is Designed For The Quantitative Laboratory Detection
Of Metalaxyl Pesticide Residues In Ground And Surface
Water Samples, With An Assay Range From 0.15 To 1.75
Parts Per Billion (Ppb).
| |
General |
|
The EnviroLogix
Metalaxyl Plate Kit is a competitive Enzyme-Linked ImmunoSorbent
Assay (ELISA). In the test, Metalaxyl pesticide residues
in the sample compete with enzyme (horseradish peroxidase)
labeled Metalaxyl for a limited number of antibody binding
sites on the inside surface of the test wells. After
a simple wash step, the outcome of the competition is
visualized with a color development step. As with all
competitive immunoassays, sample concentration is inversely
proportional to color development.
Darker
color = Lower concentration
Lighter
color = Higher concentration
The
EnviroLogix Metalaxyl Plate Kit can be used in the following
applications:
- Source Water Protection.
- Drinking Water Monitoring.
- Treated Effluent Monitoring.
- Run-Off Assessment And Monitoring.
- Point Source Testing.
- Soil Testing.

| Materials
Provided: |
Materials Required
But Not Provided: |
|
8 x |
Strips
of 12 Antibody-Coated Wells each, in plate
frame. |
|
1 x |
Vial
of Negative Control |
|
1 x |
Vial
of 0.1 ppb Metalaxyl Calibrator.
|
|
1 x |
Vial
of 0.4 ppb Metalaxyl Calibrator.
|
|
1 x |
Vial
of 1.75 ppb Metalaxyl Calibrator. |
|
1 x |
Bottle
of Metalaxyl-Enzyme Conjugate |
|
1 x |
Bottle
of Substrate. |
|
1 x |
Bottle
of Stop Solution. |
|
|
Disposable
Tip, Adjustable Air Displacement Pipette that
will measure 100 microliters (µL). |
|
|
Marking
Pen (indelible). |
|
Tape
or Parafilm. |
|
|
Timer
(1 hour and 30 minutes). |
|
Cool
Tap or Distilled Water for rinsing wells. |
|
|
Microtiter
Plate Reader or strip reader. |
|
Microtiter
Plate Washer (optional). |
|
|
Twelve-Channel
Pipette that will measure 100 µL (optional). |
|
Racked
Dilution Tubes for loading samples into the
plate with a 12-channel pipette (optional). |
|
|
Orbital Plate Shaker (optional).
|
|
| Kit
Specifications: |
| Plate
Format: |
|
| Time
Requirement: |
|
| Detection
Limit: |
|
| Quantification
Limit: |
|
Cross
Reaction: (Limit
Of Detection) |
- Metalaxyl
(0.08 ppb).
-
Dimethenamid (2.4 ppb).
-
Metolachlor (3.2 ppb).
-
Acetochlor (7.9 ppb).
-
Propachlor (46 ppb).
-
Benalaxyl (141 ppb).
-
Alachlor (36 ppb).
|
| Measurement: |
- Microtiter
Plate Reader or Strip Reader.
|
| Product
ID #: |
|
|