| EnviroLogix
Inc. - Environmental & Food Monitoring Kits: Pesticides
ORGANOCHLORINE SCREEN (ELISA Kit)
| |
Intended Use
|
The
EnviroLogix Organochlorine Screening Test Is A Qualitative
("Yes/No") Test For The Detection Of Unacceptable
Organochlorine Residues In Dried Vine And Tree Fruit.
The Tests Individually Detect Organochlorine Insecticides
From Each Of The Two Main Families: The Dieldrin (Cyclodiene)
Family, And A Family Comprising DDT (And Its Metabolites,
DDA And DDE), And Dicofol (Kelthane). However, They
Do Not Discriminate Between Members Of The Same Family.
The Test Is Designed To Have Similar Sensitivity To
Gas Chromatography (Instrumental) Analysis, And To Detect
Levels Corresponding To The Export Trade “Action Levels”
Of Each Compound.
| |
General |
|
The
EnviroLogix Organochlorine Screening Test is based on
the use of antibodies to each of the organochlorine
families. These antibodies are immobilized on wells
in different vertical colour-coded strips assembled
in alternating columns in a 96-well ELISA plate frame.
The antibodies bind both compounds from the corresponding
organochlorine group as well as an organochlorine-enzyme
conjugate. If present, the organochlorine residues
in the extract of the fruit sample compete with an organochlorine-enzyme
conjugate for a limited number of binding sites on the
antibodies.
-
A sample that may contain organochlorine is added
to a microwell, followed by organochlorine-enzyme
conjugate. The immobilized organochlorine antibodies
on the well walls compete with the organochlorineenzyme
conjugate for the same antibody binding sites.
- After
this mixture is left to sit for 60 minutes, any unbound
molecules are washed away.
- A
substrate/chromogen solution is then added to the
microwells. In the presence of bound organochlorine-enzyme
conjugate, the substrate is converted to a compound,
which causes the chromogen to turn blue. One enzyme
molecule can convert more than one substrate molecule.
The substrate molecules then convert chromogen molecules
to blue.
Since
there are the same number of immobilized antibodies
available on every microwell, and each microwell receives
the same number of organochlorine-enzyme conjugate molecules,
a sample which contains a low concentration of organochlorine
enables the immobilized antibody to bind many organochlorine-enzyme
conjugate molecules. Therefore, a low concentration
of organochlorine of a particular group will produce
a dark blue sample. Conversely, a high concentration
of organochlorine of a particular group will enable
fewer organochlorine-enzyme conjugate molecules to be
bound by the antibodies, resulting in a lighter blue
sample.

| Materials
Provided: |
Materials Required
But Not Provided: |
|
1 x |
Sachet Of Wash Buffer Salts. |
|
1 x |
Bottle
of Stop Solution. |
|
1 x |
Coated
Plate in foil bag, containing 6 DDT-coated
test strips and 6 Cyclodiene-coated test strips,
arranged in alternating columns in plate frame. |
|
1 x |
Bottle
of Diluent Buffer. |
|
1 x |
Glass
Vial Of Pesticide Standards for spiking fruit
extract. |
|
1 x |
Bottle,
Organochlorine - Enzyme conjugate concentrate. |
|
1 x |
Bottle
of Substrate. |
|
|
Microplate
Reader And Washer (optional). |
|
|
Shaker
for extracting pesticide residues from fruit;
balance for weighing fruit. |
|
Microwell
Plate Mixer. |
|
|
Positive-Displacement
Pipette (20 µL) {Microman M-25 (Gilson
Medical Electronics, France) or the equivalent}. |
|
Automatic
Pipettes (1-20, 20-200, 200-1000, 1000-5000
µL); 12-channel pipette (20-200 µL). |
|
|
Timer
or wristwatch; Marker Pens. |
|
Distilled
Water for preparing buffers. |
|
|
Glass
Bottles/ conical flasks for extracting fruit. |
|
Methanol
for extraction of the pesticide from the fruit. |
|
|
100
mL and 1 L Measuring Cylinders; Two 1 L bottles
for wash and diluent solutions. |
|
Confirmed Pesticide-Free Fruit of each variety
being analyzed (20-40 grams per test). |
|
| Kit
Specifications: |
| Plate
Format: |
|
| Time
Requirement: |
|
| Detection
Limit: |
|
| Quantification
Limit: |
|
Cross
Reaction: (Limit
Of Detection) |
- DDT/Dicofol
group (blue colour strips).
-
Dicofol 1 (0.5 ppm).
-
DDT (0.05 ppm).
-
Chlorbenzilate (0.01 ppm).
-
DDE (0.05 ppm).
-
DDA (0.01 ppm).
-
Cyclodiene group (red colour strips).
-
Dieldrin (0.02 ppm).
-
Endosulfan 1 (0.02 ppm).
-
Aldrin (0.1 ppm).
-
Chlordane (0.1 ppm).
-
Heptachlor (0.02 ppm).
-
Endrin (0.01 ppm).
|
| Measurement: |
- Microtiter
Plate Reader or Strip Reader.
|
| Product
ID #: |
|
|