ENVIROLOGIX Inc. - Environmental
& Food Monitoring Kits: Pesticides
PCB’S IN SOIL (ELISA Kit)
| |
Intended Use
|
The EnviroLogix
PCB In Soil Tube Kit Is Designed For Semi-Quantitative
Field Screening For PCB'S In Soil. The Kit Is Supplied
With Calibrators Equivalent To 1 Part Per Million (Ppm)
And 10 Ppm PCB (Arochlor 1254) In Soil. The Assay Range
Can Easily Be Extended.
| |
General |
|
The
EnviroLogix PCB in Soil Tube Kit is a competitive Enzyme-Linked
ImmunoSorbent Assay (ELISA). In the test, PCB in sample
extracts compete with enzyme (horseradish peroxidase)
labeled PCB for a limited number of antibody binding
sites on the inside surface of the test tubes. After
a simple wash step, the outcome of the competition is
visualized with a color development step. As with all
competitive immunoassays, sample concentration is inversely
proportional to color development.
Darker
color = Lower concentration
Lighter
color = Higher concentration
The
EnviroLogix PCB in Soil Tube Kit can be used in the
following applications:
- Initial Site Characterization, Mapping
- Real-Time Testing During Remediation
- Screening Negatives Prior To GC Confirmation

| Materials
Provided: |
Materials Required
But Not Provided: |
|
40 x |
Antibody-Coated
Test Tubes. |
|
1 x |
Vial
Negative Control. |
| 1 x |
Vial
1 ppm Calibrator. |
| 1 x |
Vial
10 ppm Calibrator. |
| 1 x |
Bottle
of PCB-Enzyme Conjugate. |
| 1 x |
Bottle of Substrate. |
|
1 x |
Bottle
of Stop Solution. |
|
|
EnviroLogix Soil Extraction Kit. |
|
|
Methanol
(10 milliliter (mL) per sample. |
|
Eppendorf
Repeater Pipetter 4780 (Eppendorf cat. No.
2226000-6) or equivalent. |
|
|
3,
12.5 mL Combi-Syringes (VWR Cat. No. 40000-008)
for the Eppendorf Repeater Pipette. |
|
Gilson
Microman M25 Positive Displacement Pipette
(available from Rainin) or equivalent. |
|
|
CP-250
Tips (red) for the Gilson Microman (available
from Rainin). |
|
Marking
Pen (indelible). |
|
|
Timer
(10 minutes). |
|
|
Cool
Tap Or Distilled Water for rinsing tubes. |
|
|
Photometer for reading tubes. |
|
Test
Tube Rack that can hold up to 20 antibody-coated
test tubes securely enough to flick out water. |
|
|
After
Wash Step (contact EnviroLogix for information
on obtaining an appropriate rack).
|
|
| Kit
Specifications: |
| Format: |
|
| Time
Requirement: |
|
| Detection
Limit: |
-
1242 (1.7 ppm).
-
1248 (0.6 ppm).
-
1254 (0.3 ppm).
-
1260 (0.3 ppm).
|
| Measurement: |
-
Microtiter Plate Reader or Strip Reader.
|
| Product